Warning Description


The CSS No Currnt warning will occur if one of the CSS circuits is commanded on and the Current Sensor for that circuit does not measure current.
The CCR will provide the CSS Error for applicable channels.

Attempt to correct


- Ensure the CSS equipment is operating correctly.
- Measure the circuit current with a DMM to determine if output current is present.
- Verify the output current calibration. Refer to How to Determine if Recalibration is Needed.

Airport Lighting Company | Type L-828 / L-829 Ferroresonant Constant Current Regulator

Constant Current Regulator

Related Articles

  • CCR Warning – CSS 123456 Current
    Number of Views42
  • CCR Warning – CSS 123456 Error
    Number of Views33
  • CCR Warning – CSS Input Card Failure
    Number of Views37
  • CCR Warning – Off Current High
    Number of Views35
  • CCR Warning – Output Card Fault
    Number of Views50

Trending Articles

  • Performing Megger Testing for Airfield Lighting Systems
  • Troubleshooting an L-880(L), L-881(L) Precision Approach Path Indicator Lights (PAPI)
  • L-880(L), L-881(L) Precision Approach Path Indicator Lights (PAPI) - Leveling and Tilting the Light Head (Setting the glid…
  • Testing a Bridge Rectifier
  • L-849-V-A/E / L-849-I-A/E Unidirectional Runway Approach Lights - Set Up Procedure for a 3 Step CCR
Powered by Salesforce Logo
Loading
CCR Warning – CSS 123456 No Current