Loading
×Sorry to interrupt
CSS Error
Refresh
Skip to Main Content
  • ""
Home Self Help Contact Us

Title
L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Understanding the CCR Display Screen
URL Name
Understanding-the-CCR-Display-Screen
Summary
Explains the information displayed on the main screen of the Digital Control and Monitoring Unit (DCMU) and how to interpret each field during operation.

Content

Understanding the Digital Control Monitoring Unit (DCMU) Display


The CCR display is controlled by pushing the UP, DOWN, and DOT buttons that are located below the screen. Each screen that is displayed will scroll continuously, as if on a rolling drum. Once you attempt to navigate past the last line of information, you will be returned to the first line.

The Main Screen

The main screen of the display shows the most important, at-a-glance information.

  • Current Brightness Step & Local or Remote Indication
  • Vin – Input (Source) Voltage Measurement
  • Iin – Input Current Measurement, if equipped. If not equipped, this line will show: “Iin=-----"
  • Vout – The voltage reading of the connected field output circuit
  • Iout – The current reading of the connected field output circuit
  • kVAo – The kVA calculation of the connected field output circuit
  • kWo – the kW calculation of the connected field output circuit
  • *kVAi – The kVA calculation of the supply
  • *kWi – The kW calculation of the supply
  • *PFIn – Power factor calculation of the supply
  • *PFOut – Power factor calculation of the output
  • Lamps Out – Current count of lamps out, must be configured, enabled, and calibrated. If not equipped, this line will show: “Lamps Out=---"
  • Hz – The configured AC voltage frequency
  • Temperature – Displays the current temperature reading at the DCMU in centigrade
  • Mgr – Displays the current megger reading (if equipped). Until a megger test is run, this line will show: “Mgr=?????”
  • HwVer – Hardware version of the DCMU
  • SwVr – Software version of the DCMU

    Note: The kVAi, kWi, PFIn, and PFOut options only appear on the screen if the CCR is equipped with an input CT.

Safety Reminder


Always maintain safe working conditions by using appropriate personal protective equipment (PPE) where necessary.
The display does not confirm absence of hazardous voltage.
Open all sources of electricity to the CCR and follow lock out / tag out procedures before servicing.

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Constant Current Regulator

Related Articles

  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Maintenance
    Number of Views64
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Product Overview
    Number of Views134
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Understanding the S-1 Cutout
    Number of Views72
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - How to Navigate the CCR Display and Keypad
    Number of Views80
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Fuse Overview (F1 through F5 Functions)
    Number of Views142

Trending Articles

  • Performing Megger Testing for Airfield Lighting Systems
  • L-849-V-A/E / L-849-I-A/E Runway End Identifcation Lights (REIL) - Overview and Application
  • Digital Control and Monitoring Unit (DCMU) – Overview and Function
  • Troubleshooting an L-880(L), L-881(L) Precision Approach Path Indicator Lights (PAPI)
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - How to Navigate the CCR Display and Keypad
Powered by Salesforce Logo
Loading
L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Understanding the CCR Display Screen