CCR Warning – Megger Fault
URL Name
CCR-Warning-Megger-Fault
Summary
Describes the Megger Fault warning in the Type L-828 and Type L-829 Ferroresonant Constant Current Regulator and the corrective actions.

Content

Warning Description

The CCR has determined an issue with the IRMS / Megger card.
If IRMS / Megger functionality was not installed, this warning will only be seen if the IRMS is enabled in the Configuration Menu.
When the CCR determines a warning or setpoint alarm, it will engage the indicator light and the warning will be shown on line 1 of the CCR display.
The CCR will continue to operate in the event of a warning.
Although the CCR will continue operating, warning conditions must still be noted and fixed.
Allowing the CCR to operate in a warning state may cause problems for efficiency, general safety, and longevity of equipment.

Attempt to Correct

Always maintain safe working conditions by using appropriate personal protective equipment (PPE) where necessary.
Turn off power to the CCR.
Once power has discharged and all LEDs are out, ensure the megger card connection screws are tight.
If IRMS / Megger functionality was unintentionally enabled, disable it.
To disable, navigate to Configuration Menu > Monitor Config > Disable > Auto Megger [Disable].

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Related Articles

  • CCR Warning – Megger Warning
    Number of Views29
  • CCR Warning – Megger Alarm
    Number of Views55
  • Performing Megger Testing for Airfield Lighting Systems
    Number of Views251
  • CCR Warning – Output Card Fault
    Number of Views42
  • CCR Warning – Mismatch - Failsafe
    Number of Views36

Trending Articles

  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Adjusting IRMS Warning and Alarm Thresholds
  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - 24V Internally Powered Remote Wiring
  • How to Replace the Light Engine on an L862 LED High Intensity Runway Light
  • L-880(L)/L-881(L) Precision Approach Path Indicator (PAPI) - Overview and Application
Powered by Salesforce Logo
Loading
CCR Warning – Megger Fault