Loading
×Sorry to interrupt
CSS Error
Refresh
Skip to Main Content
  • ""
Home Self Help Contact Us

Title
CCR Warning – Mismatch - Failsafe
URL Name
CCR-Warning-Mismatch---Failsafe
Summary
Describes the Mismatch - Failsafe warning in the Type L-828 and Type L-829 Ferroresonant Constant Current Regulator and the corrective actions.

Content

Warning Description


This warning may occur on CCRs with multiple communications and channels configured. If Channel A and Channel B are sending different commands to the same CCR, the CCR will go to a failsafe setting. When the CCR determines a warning or setpoint alarm, it will engage the indicator light and the warning will be shown on line 1 of the CCR display. The CCR will continue to operate in the event of a warning. Although the CCR will continue operating, warning conditions must still be noted and fixed. Allowing the CCR to operate in a warning state may cause problems for efficiency, general safety, and longevity of equipment.

Attempt to Correct


Always maintain safe working conditions by using appropriate personal protective equipment (PPE) where necessary.
Ensure the command system is sending only one command to the CCR.
Operate the CCR in Local mode.

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Constant Current Regulator

Related Articles

  • CCR Warning – Comm Loss - Failsafe
    Number of Views35
  • CCR Warning – Output Disabled
    Number of Views41
  • CCR Warning – Hardware Warning
    Number of Views32
  • CCR Warning – Megger Alarm
    Number of Views63
  • CCR Warning – No Comms Ch A
    Number of Views51

Trending Articles

  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - 24V Externally Powered Remote Wiring
  • Troubleshooting an L-880(L), L-881(L) Precision Approach Path Indicator Lights (PAPI)
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Understanding the S-1 Cutout
  • L-849-V-A/E / L-849-I-A/E Unidirectional Runway Approach Lights - Set Up Procedure for a 3 Step CCR
Powered by Salesforce Logo
Loading
CCR Warning – Mismatch - Failsafe