L-862(L), L-862E(L) High Intensity LED Runway Light - Daily and Monthly Maintenance
URL Name
L-862-L-L-862E-L-High-Intensity-LED-Runway-Light---Daily-and-Monthly-Maintenance
Summary
This article outlines the recommended daily and monthly maintenance tasks for the L-862(L) and L-862E(L) High Intensity LED Runway Light to ensure continued performance and compliance.

Content

Daily Maintenance

Visually inspect the fixture for any signs of physical damage, lens cracking, or discoloration.
Confirm the light is operating correctly at the assigned intensity step.
Report any anomalies to maintenance personnel immediately.

Monthly Maintenance

Clean the glass lens using a soft, non-abrasive cloth and approved cleaner to remove dirt, dust, or contaminants.
Inspect the lens for cracks, chips, or significant discoloration; replace if damaged.
Check mounting hardware, frangible coupling, and column for tightness and signs of corrosion or damage.
Re-torque all fasteners to the specified values listed in the torque table.
Verify the fixture remains level using the leveling surface on the cap.
Confirm aiming alignment using the sighting cross on the cap.
Inspect seals and gaskets for integrity to maintain weatherproofing.

General Notes

Disconnect power before performing any cleaning or inspection that requires close contact with the fixture.
Use only manufacturer-approved methods and materials for cleaning the lens.
For fixtures with arctic kit (option 5), inspect heater components for proper function during monthly checks.

Airport Lighting Company | L-862(L), L-862E(L) High Intensity Runway Light  

High Intensity Runway Light

Related Articles

  • L-862(L), L-862E(L) High Intensity LED Runway Light - Installation Instructions
    Number of Views178
  • L-862(L), L-862E(L) High Intensity LED Runway Light - Replacement Parts
    Number of Views64
  • L-862(L), L-862E(L) High Intensity LED Runway Light - Overview and Applications
    Number of Views72
  • L-862(L), L-862E(L) High Intensity LED Runway Light - Available Options
    Number of Views67
  • Troubleshooting an L-862(L), L-862E(L), High Intensity LED Runway Light/ L861SE(L) Medium Intensity LED Edge Light
    Number of Views100

Trending Articles

  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - 24V Externally Powered Remote Wiring
  • Troubleshooting an L-880(L), L-881(L) Precision Approach Path Indicator Lights (PAPI)
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Understanding the S-1 Cutout
  • L-849-V-A/E / L-849-I-A/E Unidirectional Runway Approach Lights - Set Up Procedure for a 3 Step CCR
Powered by Salesforce Logo
Loading
L-862(L), L-862E(L) High Intensity LED Runway Light - Daily and Monthly Maintenance