Warning Description


The CSS Current warning will occur if one of the CSS circuits is commanded off and the Current Sensor for that circuit measures current.
The CCR will provide the CSS Current warning for applicable channels.

Attempt to correct


- Ensure the CSS equipment is operating correctly.
- Measure the circuit current with a DMM to determine if output current is present.
- Verify the output current calibration. Refer to How to Determine if Recalibration is Needed.

Airport Lighting Company | Type L-828 / L-829 Ferroresonant Constant Current Regulator

 

Constant Current Regulator

Related Articles

  • CCR Warning – CSS 123456 No Current
    Number of Views33
  • CCR Warning – CSS 123456 Error
    Number of Views33
  • CCR Warning – CSS Input Card Failure
    Number of Views36
  • CCR Warning – Off Current High
    Number of Views33
  • CCR Warning – Output Disabled
    Number of Views41

Trending Articles

  • Performing Megger Testing for Airfield Lighting Systems
  • L-880(L)/L-881(L) Precision Approach Path Indicator (PAPI) - Overview and Application
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Understanding the S-1 Cutout
  • L-849-V-A/E / L-849-I-A/E Unidirectional Runway Approach Lights - Set Up Procedure for a 3 Step CCR
  • L-862(L), L-862E(L) High Intensity LED Runway Light - Overview and Applications
Powered by Salesforce Logo
Loading
CCR Warning – CSS 123456 Current