Describes the Input Card Error warning in the Type L-828 and Type L-829 Ferroresonant Constant Current Regulator and the corrective actions.

Content

Warning Description


The CCR has determined an error with the input card on the DCMU. When the CCR determines a warning or setpoint alarm, it will engage the indicator light and the warning will be shown on line 1 of the CCR display. The CCR will continue to operate in the event of a warning. Although the CCR will continue operating, warning conditions must still be noted and fixed. Allowing the CCR to operate in a warning state may cause problems for efficiency, general safety, and longevity of equipment.

Attempt to Correct


Always maintain safe working conditions by using appropriate personal protective equipment (PPE) where necessary.
Turn off power to the CCR.
Once power has discharged and all LEDs are out, remove the green terminal blocks from the bottom of the DCMU.
Ensure all screws are tight.
Reinstall the terminal blocks.
Ensure they are seated fully.

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Constant Current Regulator

Related Articles

  • CCR Warning – CSS Input Card Failure
    Number of Views34
  • CCR Warning – Output Card Fault
    Number of Views45
  • CCR Warning – Firing Card Warning
    Number of Views35
  • CCR Warning – CSS 123456 Error
    Number of Views31
  • CCR Warning – Low Input Voltage
    Number of Views34

Trending Articles

  • L861 LED Medium Intensity Elevated Edge Light - Replacement Parts
  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Completing In-Field Recalibrations
  • L-862(L), L-862E(L) High Intensity LED Runway Light - Installation Instructions
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Fuse Overview (F1 through F5 Functions)
Powered by Salesforce Logo
Loading
CCR Warning – Input Card Error