L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Configuring Automatic Megger (IRMS)
URL Name
Configuring-Automatic-Megger-IRMS
Summary
Explains how to configure automatic insulation resistance monitoring using the CCR IRMS feature.

Content

Overview


The CCR IRMS system may be configured to automatically monitor insulation resistance of the series circuit. Automatic monitoring allows the CCR to periodically check circuit integrity and generate alerts if resistance drops below configured thresholds. This feature supports preventative maintenance and early fault detection.

Purpose of Automatic IRMS


Automatic monitoring is used to detect developing ground faults, identify insulation degradation, alert operators to abnormal leakage conditions, and provide trend data over time. Automatic monitoring reduces reliance on manual testing.

When to Enable Automatic Monitoring


Enable automatic IRMS when continuous monitoring is required, the system includes IRMS capability, or maintenance policy supports automated alerts. Do not enable without understanding the impact of alarms and warnings.

Configuration Procedure


Power the CCR. Press CONFIG. Enter password 9999. Navigate to the IRMS or Megger settings. Enable Automatic Monitoring. Configure resistance warning and alarm thresholds as required. Save the configuration.

Threshold Settings


Automatic IRMS allows configuration of warning threshold and alarm threshold. If measured insulation resistance falls below the warning threshold, a warning may be generated. If measured insulation resistance falls below the alarm threshold, a fault condition may be generated. Threshold values must match system requirements.

After Enabling


After configuration, verify IRMS function is active. Confirm thresholds are correctly set. Monitor the system for initial readings. Record baseline insulation resistance. Trending over time improves maintenance planning.

Troubleshooting Automatic IRMS


If repeated warnings occur, inspect series circuit for moisture. Check recent field work. Compare current reading to historical baseline. Run a manual Megger test to confirm. If nuisance alarms occur, review threshold settings. Confirm environmental conditions are not influencing readings.

Safety Reminder


Automatic IRMS applies test voltage to the series circuit. Ensure maintenance personnel are aware that insulation testing may occur automatically. Do not work on the field circuit while automatic testing is enabled.

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Constant Current Regulator

Related Articles

  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Product Overview
    Number of Views129
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Maintenance
    Number of Views61
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Interpreting Megger (IRMS) Results
    Number of Views49
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Running a Manual Megger (IRMS) Test
    Number of Views70
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Fuse Overview (F1 through F5 Functions)
    Number of Views138

Trending Articles

  • L861 LED Medium Intensity Elevated Edge Light - Replacement Parts
  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Completing In-Field Recalibrations
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Product Overview
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Maintenance
Powered by Salesforce Logo
Loading
L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Configuring Automatic Megger (IRMS)