This article provides the recommended maintenance intervals, tasks, and specific actions for the LED REIL (L-849(L)) and ODAL (L-859(L)) systems to ensure reliable operation, including daily visual checks, bi-weekly lens cleaning, monthly alignment and cabinet inspections, and yearly structural and wiring verification.

Content

Maintenance Guideline

The LED REIL system should be properly maintained and inspected for reliable operation. The following chart provides a guideline to follow to maintain the system.

Daily

Visual check of operation:
Verify Operation
Verify Flash Rate

 

Bi-Weekly

Visual check of lens:
Clean Lens
Check for cracks
Check for condensation/moisture

Check for vegetation growth or bird droppings:
Remove any obstructions near system clean  system as required

 

Monthly

Verify OFH Alignment:
Realign as required

Verify Interlocks: 
Open PCU and SCU to verify safety devices

Check for FOD within cabinets:
Open cabinets and clean any debris

Verify Manual Operation:
Manually adjust mode of system

 

Yearly

Verify OFH Alignment:
Realign as required

Verify mounting columns:
Align and tighten all EMT connections

Check seals and foam plug:
Verify all door seals and foam plug intact

Check internal wiring:
Verify all wires are seated and not damaged

 

General Maintenance Notes

Perform all maintenance tasks at the specified intervals to ensure continued reliable flashing, proper intensity, and compliance with photometric requirements. Cleaning the lens removes contaminants that reduce effective intensity and visibility. Alignment verification maintains correct beam projection for runway end identification or approach guidance. Cabinet inspections prevent moisture, debris, or vegetation from affecting electrical components or safety interlocks. Tightening EMT connections and checking seals preserves structural integrity and weatherproofing. All work must be performed with power disconnected and lockout/tagout procedures followed.

Airport Lighting Company | L-849(L) REIL Runway End Identification LightL-859(L) ODAL OMNI Directional Approach Light  

Related Articles

  • L-849(L) REIL Runway End Identification Light/L-859(L) ODAL OMNI Directional Approach Light - Replacement Parts
    Number of Views65
  • L-849(L) REIL Runway End Identification Light/L-859(L) ODAL OMNI Directional Approach Light - Installation Instructions
    Number of Views59
  • L-849(L) REIL Runway End Identification Light/L-859(L) ODAL OMNI Directional Approach Light - Available Options
    Number of Views46
  • L-849(L) REIL Runway End Identification Light/L-859(L) ODAL OMNI Directional Approach Light - System Operation
    Number of Views68
  • L-849(L) REIL Runway End Identification Light/L-859(L) ODAL OMNI Directional Approach Light - Overview and Application
    Number of Views88

Trending Articles

  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Operating Modes and Output Current Settings
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Remote Control Overview
  • L-849(L) REIL Runway End Identification Light/L-859(L) ODAL OMNI Directional Approach Light - Replacement Parts
  • Troubleshooting an L849(L) SAL-1030 Runway End Identifier Light (REIL) System
Powered by Salesforce Logo
Loading
L-849(L) REIL Runway End Identification Light/L-859(L) ODAL OMNI Directional Approach Light - Maintenance