Content

Background on Lamp Out Feature


The Lamp Out feature is optional and is only available on the Type L-829 CCR. It is not present on the Type L-828. The Lamp Out feature monitors the series circuit for failed lamps by comparing the measured circuit current to the expected current for the selected brightness step and the configured number of lamps. If the current drops below the calculated threshold for the number of lamps out, a Lamp Warning or Lamp Alarm may be triggered. The feature requires accurate configuration of the number of lamps and periodic calibration to function correctly. If the Lamp Out feature is not installed on your CCR (i.e., L-828 model) and a Lamp Warning appears, it may be necessary to disable the feature in CCR Configuration to prevent false warnings.

Warning Description


The lamp warning threshold has been met. When the CCR determines a warning or setpoint alarm, it will engage the indicator light and the warning will be shown on line 1 of the CCR display. The CCR will continue to operate in the event of a warning. Although the CCR will continue operating, warning conditions must still be noted and fixed. Allowing the CCR to operate in a warning state may cause problems for efficiency, general safety, and longevity of equipment.

Attempt to Correct


Always maintain safe working conditions by using appropriate personal protective equipment (PPE) where necessary.
The connected circuit has lamps that are approaching failure or are out of tolerance.
Replace lamps as needed.
If no lamps are out of tolerance or the incorrect status is displayed, refer to Lamp Out for more information about the Lamp Out feature and calibration procedures.
If the Lamp Out feature is not installed (Type L-828), disable it in CCR Configuration to clear false warnings.

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Related Articles

  • CCR Warning – Lamp Alarm
    Number of Views39
  • CCR Warning – Mismatch - Failsafe
    Number of Views44
  • CCR Warning – Output Disabled
    Number of Views41
  • CCR Warning – Hardware Warning
    Number of Views32
  • CCR Warning – Megger Alarm
    Number of Views63

Trending Articles

  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - 24V Externally Powered Remote Wiring
  • Troubleshooting an L-880(L), L-881(L) Precision Approach Path Indicator Lights (PAPI)
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Understanding the S-1 Cutout
  • L-849-V-A/E / L-849-I-A/E Unidirectional Runway Approach Lights - Set Up Procedure for a 3 Step CCR
Powered by Salesforce Logo
Loading
CCR Warning – Lamp Warning