Loading
×Sorry to interrupt
CSS Error
Refresh
Skip to Main Content
  • ""
Home Self Help Contact Us

Title
Input Surge Arrestor – Function in the CCR
URL Name
Input-Surge-Arrestor-Function-in-the-CCR
Summary
Explains the purpose of the input surge arrestor and its role in protecting the Type L-828 and L-829 Constant Current Regulators from transient voltage events.

Content

Overview


The input surge arrestor is installed on the incoming line side of the CCR. Its purpose is to protect internal components from voltage transients and surge events.

Primary Function


The input surge arrestor diverts transient voltage spikes. It protects the input circuitry. It helps prevent damage to internal components. Surges may be caused by utility switching events, lightning activity, or power system disturbances. The arrestor limits overvoltage exposure to the regulator.

Location in the System


The input surge arrestor is connected across the incoming power lines. It operates independently of the control system. Its function is passive and protective.

Protection Scope


The input surge arrestor protects the control transformer, input contactor, SSR circuitry, firing card, and DCMU. It does not regulate voltage during normal operation. It only responds during transient conditions.

Failure Considerations


If the input surge arrestor fails, surge protection may be reduced. Additional internal damage could occur during a transient event. Inspection should be performed if surge events are suspected.

Service Considerations


Before servicing, de-energize input power. Follow lockout/tagout procedures. Verify absence of voltage. Surge arrestors are connected to line voltage and must be treated as energized until verified safe.

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Constant Current Regulator

Related Articles

  • Output Surge Arrestors – Function in the CCR
    Number of Views49
  • Input Contactor – Operation and Function in the CCR
    Number of Views52
  • Current Transformers (CTs) – Function in the CCR
    Number of Views46
  • Solid State Relay (SSR) – Function in the CCR
    Number of Views45
  • Firing Card – Control Interface and Function in the CCR
    Number of Views58

Trending Articles

  • Troubleshooting an L849(L) SAL-1030 Runway End Identifier Light (REIL) System
  • CCR Fault – Over Voltage
  • L-880(L)/L-881(L) Precision Approach Path Indicator (PAPI) - Overview and Application
  • Troubleshooting an L-880(L), L-881(L) Precision Approach Path Indicator Lights (PAPI)
  • Testing a Bridge Rectifier
Powered by Salesforce Logo
Loading
Input Surge Arrestor – Function in the CCR