Warning Description


The CCR is providing output current, but the voltage is minimal.
TURN The CCR providing output current, but the voltage is minimal.
The most likely cause is an S-1 Cutout shorting the output, or a forgotten wire jumper used during setup/calibration.
The CCR will operate in a short, and is providing power to the output terminals.

Attempt to Correct


Always maintain safe working conditions by using appropriate personal protective equipment (PPE) where necessary.
Go into Monitor Config > Output Voltage and disable it, if the warning disappears re enable if desired and configure the appropriate threshold determined by load.
TURN OFF POWER to the CCR before modifying the output circuit.
Ensure the circuit S-1 Cutout is set for normal operation.
Open the CCR door and visually inspect for a short, such as a leftover wire jumper from installation.
If there is still a short, disconnect airfield circuit and test for a circuit short.

Airport Lighting Company | Type L-828, Type L-829 Ferroresonant Constant Current Regulator

Constant Current Regulator

Related Articles

  • CCR Warning – Output Disabled
    Number of Views42
  • CCR Warning – Output Card Fault
    Number of Views50
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Operating Modes and Output Current Settings
    Number of Views98
  • CCR Warning – High Temperature
    Number of Views52
  • CCR Warning – Mismatch - Failsafe
    Number of Views44

Trending Articles

  • Digital Control and Monitoring Unit (DCMU) – Overview and Function
  • Input Contactor – Operation and Function in the CCR
  • Performing Megger Testing for Airfield Lighting Systems
  • L-828, Type L-829 Ferroresonant Constant Current Regulator (CCR) - Remote Control Overview
  • CCR Warning – CSS 123456 No Current
Powered by Salesforce Logo
Loading
CCR Warning – Output Shorted